Library of Ashurbanipal · MELEK

Library›Plants and preparation›Measuring Tools Scales Syringes and Volumetric Dosing

Measuring Tools Scales Syringes and Volumetric Dosing

Measuring Tools: Scales, Syringes and Volumetric Dosing is the equipment page of Dosing in Liquids. It covers what each measuring tool can and cannot do, how much error each one carries, how to check them, and the aliquot (volumetric dosing) method for amounts too small to weigh directly.

Scales

Readability is not accuracy

A scale that shows 0.001 g ("milligram scale") displays milligrams. That does not mean it is accurate to a milligram. Three different numbers matter:

Inexpensive 0.01 g pocket scales typically repeat to within about ±0.01–0.03 g. Inexpensive 0.001 g scales typically manage about ±0.002–0.005 g, and only when used well. Find out what yours actually does by testing it (below).

Checking a scale

  1. Put it on a hard, level, vibration-free surface, out of drafts, fans and air-conditioning vents. Let it warm up for a few minutes.
  2. Calibrate it with the weight it was designed for, following the manual.
  3. Check it with a separate known weight (calibration weights are sold in OIML classes such as M1, F2 and F1, or ASTM classes; even a cheap certified set beats none). Weigh it 10 times, lifting it off each time.
  4. Note the spread. Twice the standard deviation of those readings is a fair estimate of your weighing error at small loads.
  5. Check it again whenever the scale is moved, dropped or a battery is changed.

Common errors: static on plastic weigh boats (use paper, metal or glass, or touch a grounded object first), breath and hand warmth on 0.001 g scales (use tweezers and close the draft shield), weighing near the scale's capacity limit, weighing a warm container (rising air makes it read light), and weighing a liquid that is still evaporating (alcohol).

The minimum weighable quantity rule

Pharmacy textbooks give a simple rule for the smallest amount you may weigh on a given balance and stay within an acceptable error:

Minimum weighable quantity = balance error (sensitivity) ÷ acceptable fractional error

The pharmacopoeial standard for analytical balances, USP General Chapter <41>, makes the same point more strictly. A balance is fit for a given minimum weight only if twice the standard deviation of replicate weighings, divided by that weight, is no more than 0.10%. Good weighing practice is described in USP <1251>.

The aliquot method (volumetric dosing)

This is the standard answer to "my dose is too small to weigh".

Liquid aliquot, step by step

  1. Decide the dose (say 2 mg) and the dose volume you can measure well (say 0.5 mL with a 1 mL oral syringe). The target concentration is therefore 4 mg/mL.
  2. Pick an amount above your scale's minimum weighable quantity. With the ±4 mg 0.001 g scale above, 200 mg gives about ±2%.
  3. Volume needed = 200 mg ÷ 4 mg/mL = 50 mL.
  4. Weigh 200 mg. Dissolve it in part of a suitable solvent. Transfer it to a 50 mL graduated cylinder or volumetric flask, rinse the weighing vessel into it, and top up to the 50 mL mark. Mix by inverting 20 times or more.
  5. Every 0.5 mL now contains 2 mg.

Solid aliquot (geometric dilution), for powders

  1. Weigh an amount above the minimum weighable quantity, e.g. 120 mg of active.
  2. Mix it with an equal volume of an inert diluent (lactose, microcrystalline cellulose, powdered sugar, maltodextrin) and blend thoroughly. Then add diluent equal to the mixture's volume and blend again, and keep doubling until the diluent is all in. This is geometric dilution, and it avoids the uneven blend you get from dumping a small amount of active into a large amount of diluent.
  3. For example, 120 mg active + diluent to a total of 960 mg = 1 part in 8. Then 120 mg of the blend contains 15 mg of active.
  4. Powders can segregate when particle sizes differ, so shaking a jar can unmix it. Liquid aliquots are usually more reliable.

Measuring volume

Oral syringes (best for doses)

Pipettes

Graduated cylinders and volumetric flasks

Droppers

Kitchen spoons and cups

Gravimetric dosing: weighing liquids

Weighing a liquid on a 0.01 g scale is often more accurate than reading a cup.

Error budget

Errors add up. Roughly add the percentage errors of every step for a worst-case figure:

See also

Sources

Coverage

Scale readability, repeatability and accuracy; checking a scale with calibration weights; the minimum weighable quantity rule with worked figures for 0.01 g and 0.001 g scales and the USP <41> criterion; liquid and solid (geometric dilution) aliquot methods step by step; oral syringes, pipettes, cylinders, volumetric flasks, droppers and kitchen spoons with their typical errors; dropper calibration; gravimetric dosing and weighing by difference; a worked error budget.

Videos

Watch videos about Measuring Tools Scales Syringes and Volumetric Dosing on YouTube ↗

Videos are found by the article's title on YouTube and are not reviewed or endorsed by the Library.

Filed under  Plants and preparation