Colloids in Cerebrospinal Fluid: Lange Gold Test, Oncotic Pressure and Nanoparticles covers three places where colloids and the spinal fluid meet. The first is the Lange colloidal gold test (1912), in which a gold sol was used to read the proteins of cerebrospinal fluid (CSF) and diagnose neurosyphilis and, later, multiple sclerosis, together with its relatives, the mastic and benzoin tests. The second is the colloid (oncotic) osmotic pressure of CSF compared with plasma. The third is modern research on whether gold and silver nanoparticles cross the blood–brain barrier and reach the brain and CSF, separating what is established from what is experimental. Making colloids is covered in Making Colloidal Silver A Step-by-Step Guide, and their chemistry in Colloidal Metals, Electrochemistry, and Nanoparticles.

The Lange colloidal gold test

Origin

Carl Lange, a German physician, introduced the reaction in 1912 and published it in full in 1913 ("Die Ausflockung kolloidalen Goldes durch Zerebrospinalflüssigkeit bei luetischen Affektionen des Zentralnervensystems", Zeitschrift für Chemotherapie). For about sixty years it was a standard CSF test, run alongside the cell count, total protein and the Wassermann reaction.

The principle

A gold sol is a colloid of negatively charged gold particles, ruby red from the gold plasmon band near 520 nm. Salt makes it flocculate. As the particles clump, the colour shifts from red through purple and blue and finally disappears as the gold settles out. Proteins change how easily this happens:

Normal CSF has very little protein (about 15–45 mg/dL, against 6–8 g/dL in plasma) and does not disturb the sol. Diseases that make the nervous system produce its own immunoglobulin, chiefly neurosyphilis and multiple sclerosis, change the albumin-to-globulin balance. That change shows up as a characteristic pattern of colour change across a dilution series. In modern terms, the test was an indirect, semi-quantitative readout of the γ-globulin to albumin ratio. It could not measure either protein directly.

How it was run

  1. Ten small test tubes. CSF was diluted in 0.4% sodium chloride in a doubling series: 1:10, 1:20, 1:40 … 1:5120.
  2. A fixed volume of standardised gold sol was added to each tube, classically 5 mL to 1 mL of diluted CSF.
  3. The tubes were left to stand, usually read after 12–24 hours.
  4. Each tube was graded 0 to 5: 0 = red (unchanged), 1 = red-blue, 2 = lilac or purple, 3 = blue, 4 = pale blue, 5 = colourless (complete precipitation). The ten grades were written as a ten-digit "curve".

Batches of gold sol varied, so the test was hard to reproduce between laboratories. Lange and Harris (1944) addressed this with a citrate-reduced gold sol of controlled pH and particle size, in effect an early standardised version of the citrate method later formalised by Turkevich (1951).

Reading the curves

Clinicians treated the curve as supportive, not diagnostic. Early series found it did not always match the Wassermann reaction or the cell count. Kabat and colleagues (1948) showed its sensitivity and specificity for MS were low and varied between laboratories.

The mastic and benzoin tests

The same idea was tried with other colloids:

Neither proved more specific than gold, and both disappeared with it.

Why it was replaced

The gold test is thus a direct ancestor of modern CSF immunology. Its "first-zone curve" was a colloid-chemistry readout of the same intrathecal IgG that oligoclonal bands measure.

Colloid (oncotic) osmotic pressure: CSF vs plasma

Nanoparticles and the blood–brain barrier

What is established

What is experimental

See also

Sources

Coverage

Colloids and the spinal fluid. Lange's 1912 colloidal gold reaction: principle (protective albumin vs flocculating globulin), the ten-tube 1:10 to 1:5120 dilution protocol, the 0–5 colour grading, and the paretic / first-zone, luetic / mid-zone and meningitic / end-zone curves with their diseases (neurosyphilis, MS, meningitis) and limits. The mastic (Emanuel 1915) and benzoin (Guillain 1920) tests. Replacement by electrophoresis, the IgG index and oligoclonal bands. Colloid oncotic pressure in CSF vs plasma and why crystalloid osmolality governs brain water. What is established about gold and silver nanoparticles reaching the brain (rodent biodistribution, slow clearance, human neurotoxicity case) and what is experimental (targeted delivery, NU-0129, CNM-Au8).